> For the complete documentation index, see [llms.txt](https://docs.quant-aq.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.quant-aq.com/technical-advisory-notices/technical-advisory-notices/tan002-smart-solar-power-system-mppt-controller-battery-mode-failure.md).

# TAN002 - Smart Solar Power System MPPT Controller Battery Mode Failure

Power failure affecting devices powered by Smart Solar Power Systems following a prolonged outage.

{% hint style="info" %}
This issue does not impact the safety of the battery in any way, and there is no immediate action that is required. This issue does not affect the performance of the Smart Solar Power System, only our ability to log performance data.
{% endhint %}

## Issue summary

The third-party vendor that supplied the batteries used in the Smart Solar Power System has informed QuantAQ of an issue affecting a subset of the batteries. When the battery voltage fully discharges to the point where the Multi-Point Power Tracking (MPPT) controller and Battery Management System lose power, their settings revert to factory defaults. These default settings do not support the LiFePO4 cells used in the Smart Solar Power System and lead to battery malfunction.

This does not happen under normal conditions, as the battery has a sufficient gap between when the sensor shuts off and when the MPPT controller resets. However, if the MPPT controller is left turned on for long periods of time (>2 weeks), this failure can occur. In practice, this can happen when:

* the battery is deployed for long periods of sub-zero temperatures
* the battery is put in long-term storage with the solar panels connected, a MODULAIR-X sensor connected, or a DC-DC converter connected

## Identifying impacted devices

A sensor connected to a battery exhibiting this issue will repeatedly go offline or stay offline indefinitely. All LEDs on the base of the battery will be fast flashing.

## Issue mitigation

Contact QuantAQ support if this issue is observed.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.quant-aq.com/technical-advisory-notices/technical-advisory-notices/tan002-smart-solar-power-system-mppt-controller-battery-mode-failure.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.